XMT *908 Series Intellektiv temperaturkontroll meter

Instruktionsmanual

Ⅰ 、 Huvudteknisk specifikation

L Mätavvikelse: ≤ ± 0,5%F · S ± 1

l Kallt slutkompenserande avvikelse: ≤ ± 2,0 ℃

L Provtagningscykel: 0,5S

L Kontrollcykel: Reläutgång 2 ~ 120 -tal, andra är 2s.

l Reläutgång Kontaktkapacitet: AC250V/7A (motståndsbelastning) eller AC250V/0.3A (perceptuell belastning)

l Kör kontrollerbar pulsutgång: ≥3V Räckvidd, ≥40us bredd är över noll eller trigger Kontaktpuls

l Kör fast relä signalutgång: Kör elektrisk ström ≥15 mA, spänning ≥9V.

L Kontinuerlig PID: 0 ~ 10mA (Last 500 ± 200Ω), 4 ~ 20 mA (belastning 250 ± 100Ω),

eller 0 ~ 5V (belastning ≥100KΩ), 1 ~ 5V (belastning ≥100KΩ)

L Strömförsörjning: AC85V ~ 242V, 50/60Hz

l Arbetsvillkor: Temperatur 0 ~ 50,0 ℃, relativ luftfuktighet <85%RH, utan korrode och stark elektrisk strålning.

Ⅱ 、 Produktkod:

Xmt 9 8

(1) ⑵ (3) (4) (5)

(1) Mätarens ansiktsplattdimension

Blank: 160mm × 80mm x 120mm installationshål: 152mm x 76mm

A: 96mm x 96mm x 110mm installationshål: 92mm x 92mm

D: 72mm x 72mm x 110mm installationshål: 68mm x 68mm

E: 48mm x 96mm x 110mm installationshål: 44mm x 92mm

F: 96mm x 48mm x 110mm installationshål: 92mm x 44mm

S: 80mm x 160mm x 120mm installationshål: 76mm x 156mm

G: 48mm x 48mm x 110 mm installationshål: 44 mm x 44mm

(2) Design serienummer

(3) larm

“0”: No Alarm “1or2”: Ett larm (övre gräns, nedre gräns) “5”: Röstlarm

“3”: Två grupplarm (övre gräns, nedre gräns, positiva avvikelselarm och negativa avvikelselarm diskretionär inställning)

(4) insignal

“8”: Gratis utbyte av insignalen

⑸ Kontrolmetod

Blank: reläkontakt

“A”: Enfas över-noll triggerjustering

“A3”: Trefas över-noll triggerjustering

“B”: Enfasskiftfasutlösningsjustering

“B3”: Tre-fas skiftfasutlösarjustering

“C”: 0-10 mA eller 4-20 mA konstant elektrisk strömutgång

“G”: SSR -produktion (Solid State Relay (SSR)

Ⅲ 、 Panelinstruktion (konsult)

1

Ⅳ 、 Kodinställningsläge

Series

Code

Name

Setting range

Manual

Remarks

0

SP

Appointed data

Determined by P-SL P-SH

50.0

1

AL-1

Alarm 1

Determined by P-SL,P-SH when the upper and lower limit range,it is050.0 when the upper and lower limit deviation alarm

Alarm 1 setting value

10

2

AL-2

Alarm 2

Determined by P-SL,P-SH when the upper and lower limit range,it is050.0 when the upper and lower limit deviation alarm

Alarm 1 setting value

10

3

P

Proportion modulus

0100

When the P↑,the the proportion function

When P=0,the meter is ON/OFF control

8

4

I

Calculus time

02000S

240

5

d

differential time

0200S

30

6

At

Setting itself

ON:open setting inself function

OFF:close setting itself function

Select of setting itself

OFF

7

t

SSR proportion Control period

1120S

the movements cycle ON/OFF of Setting relays control is no meaning

20

8

Hy

Main control by

drop in level

0.150.0

Only have meaning when main control output is ON/OFF(P=0)

1.0

9

Hy-1

Alarm 1

drop in level

0.150.0

It has use drop in level setting of alarm contact output

1.0

10

Hy-2

Alarm 2

drop in level

0.150.0

It has use dropin level setting of alarm contact output

1.0

11

Pb

Sensor error amendment

±20.0

The sensor have deviation can use item to revisal

0

12

FILT

Filt modulus

050

Is the software filter constants of  measurement sampling.The constant ,the Measurements antijamming capabilityMeasurements antijamming capability↑,but the measurement and system time

20

13

dp

Show accuracy

01

0: have radix point,1: have no radix point

14

P-SH

Display the high limit

P-SL9999

Can set the high limit displaying input signal

400

15

P-SL

Display the low limit

-1999P-SH

Can set the low limit displaying input signal

0

16

OUTL

Allow exports  min value

0OUTH

It will no role when highest outputlimit,,manual and position.

200.0

17

OUTH

Allow exports  max value

OUTL200

It will no role when lowest outputlimit,,manual and position.

0.0

18

ALP1

Alarm1  and output definition

04

‘0’:indicate no alarm

‘1’:upper limit touch alarm

‘2’:lower limit touch alarm

‘3’:upper windage alarm

‘4’:lower windage alarm

19

ALP2

Alarm2  and output definition

04

20

COOL

System function choice

01

‘0’:reverse control

‘1’:positive control

0

21

OPPO

Open power output

0100

Soft start functionthat meters coefficient after first export of electric power

0

22

LOCK

Code lock

050

0- all the parameter can be revised

1- only the sp can be revised

0

23

Sn

Input type

070.

0-CU50 (-50.0150.0) ;1-PT1 (-200.0200.0) ;2-PT2 (-200.0600.0) ;3-K (01300) ;4-E (0700.0) ;5-J (0900.0) ;6-T (-200400.0) ;7-S (01600) ;

24

OP-A

Output type

14

1- RLP SSR output mode

2- SSR solid state relay

3- Zero controllable silicon contact signal when it exceed zero output mode

4- Mut controllable silicon phase trigger contact output mode

5- 0~10MA linearity  control electric current output

6- 4~20MA  linearity  control electric current output


Ⅴ 、 Tekniska index

1 、 Det första inställningsområdet

Tryck på SET -tangenten 3S Enter i det första inställningsområdet, mätaren visar parameterkoden 1 ~ 24 i fönstret vid den övre raden och visar parameterdata vid den låga raden. Tryck på denna tid 、 、 ▼ ▼ eller T -tangenten för att justera parametern och tryck sedan på set -tangenten för att bevara. Tryck på SET -tangenten Lång tid kommer att dra tillbaka eller trycka på set + ƒ Knappen kommer direkt att dra sig tillbaka. Om du inom 10 sekunder inte trycker på varje knapp kommer den automatiskt att bevara data och dra tillbaka inställningen.

2 、 Det andra inställningsområdet

När mätaren är inställd med el, tryck på SET -tangenten Enter i det andra inställningsområdet, kan du enligt 1 för att ställa in "SP".

3 、 Manuell reglering

När mätaren är inställd med el, tryck på T -tangenten om 3S Enter i den manuella förordningen, kommer den att visa “H” vid den nedre raden, under denna tid kan ställa ut utgångseffekten; Tryck på T -tangenten ungefär 3s igen kommer den att dra tillbaka den manuella förordningen.

Ⅵ 、 Sätt sig själv

Mätaranvändningen under första gången eller omgivningen har växlare, och tycker att den kontrollerar inte bra, under den här tiden behöver du använda själva inställningen. Till exempel:

Den första uppsättningen AT = på, är lätt flimmer, mätaren går in i inställningen själv, tryck på SET -tangenten Enter i parameterinställningen. Ställ in HY är 0,5 ~ 1 ℃, om utgången är relä Ställ in t = 2s, har mätaren tre gånger vibrat, automatisk konserverad P, I, D -parameter och At Light Off, själva inställningen.

Ⅶ 、 Anslutningsschema (konsult)

2

★ Anmärkning : Vårt företag kommer att förbättra produkttekniken 、 Design och specifikation , det bekräftas till objektet.


  • Tidigare: XMT-808 Series Universal Input Type Intelligent temperaturkontroller
  • Nästa: FC-040 Enkel inmatningstyp Intelligent temperaturkontroller

  • Skicka förfrågan

    Produktvarning

    Prenumerera på dina intresserade nyckelord. Vi skickar fritt de senaste och hetaste produkterna till din inkorg. Missa inte någon handelsinformation.